UP-7000 Multi-parameter
Siffofin
• 12.1" babban ƙudurin TFT nuni tare da hasken baya na LED
• Binciken arrhythmia da ma'aunin ST
Kariya daga fitarwar defibrillator
• Yanayin auna manya/na yara/na jariri
• Ƙararrawa na gani da ji;Iyawar hanyar sadarwa
• Har zuwa nau'ikan igiyoyi 9 suna nunawa a lokaci guda
• 140-hour ECG ajiyar bayanai na waveform da kuma tunawa
• Yanayin bayanai na sa'o'i 2000 tare da hoto mai hoto da ra'ayi
• taron ƙungiyoyin 2000, ARR da ajiya na SpO2
• Batir lithium da aka gina;Taba allo na zaɓi
Tsarin tsari
NIBP | Dabaru | Oscillometric |
Yawancin lokacin aunawa | <30 seconds (na al'ada balagagge cuff) | |
Matsin hauhawar farashin farashi na farko | Girma: <175mmHg | |
Likitan Yara: <135mmHg | ||
Neonate: <65mmHg | ||
Ƙimar kariya ta wuce gona da iri | Girma: 300mmHg | |
Likitan Yara: 240mmHg | ||
Neonate: 150mmHg | ||
Ma'auni kewayon | ||
Systolic matsa lamba | Girma: 40mmHg ~ 275mmHg | |
Likitan Yara: 40mmHg ~ 200mmHg | ||
Neonate: 40mmHg ~ 135mmHg | ||
Diastolic matsa lamba | Girma: 10mmHg ~ 210mmHg | |
Likitan Yara: 10mmHg ~ 150mmHg | ||
Neonate: 10mmHg ~ 95mmHg | ||
Ma'anar matsa lamba na jijiya | Girma: 20mmHg ~ 230mmHg | |
Likitan Yara: 20mmHg ~ 165mmHg | ||
Neonate: 20mmHg ~ 110mmHg | ||
Daidaiton aunawa | Matsakaicin matsakaicin bambanci: ± 5 mmHg | |
Matsakaicin daidaitattun sabawa: 8 mmHg | ||
Yanayin aunawa | Manual, Auto, STAT | |
Tsakanin aunawa ta atomatik | 1 ~ 480 min | |
TEMP | Ma'auni kewayon | 21.0°C ~ 50.0°C |
Auna daidaito | ± 0.2 ° C don kewayon 25.0 ° C ~ 45.0 ° C | |
SpO2 | Mai fassara | Dual-wave tsawon LED |
SpO2 kewayon aunawa | 0% ~ 100% | |
SpO2 auna daidaito | 2% don kewayon daga 70% zuwa 100% | |
Low perfusion aiki | Kasa da 0.4% | |
Ma'auni na PR | 0bpm ~ 250bpm | |
PR auna daidaito | ± 2bpm ko ± 2%, duk wanda ya fi girma | |
ECG | Shigar da iyaka mai ƙarfi | ± 0.5mVp ~ 5mVp |
Ma'auni na HR | 15bpm ~ 350bpm | |
HR auna daidaito | ± 1% ko ± 2bpm, duk wanda ya fi girma | |
Lokacin jinkirin ƙararrawar HR | ≤10s | |
Zabin hankali | ×1/4, ×1/2, ×1, ×2, ×4 da Auto | |
Gudun sharewa | 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s | |
ECG matakin amo | ≤30µVp-p | |
ECG shigar madauki na yanzu | ≤0.1µA | |
Daban-daban shigarwar impedance | ≥10Mohm | |
Ra'ayin kin amincewa da yanayin gama gari(CMRR) | ≥105dB (Yanayin kulawa) | |
≥89dB (Yanayin bincike) | ||
Tsawon lokaci | ≥0.3s (Yanayin kulawa) | |
≥3.2s (Yanayin bincike) | ||
RESP | RR auna kewayon | 0rpm ~ 120rpm |
R auna daidaito | ± 5% ko ± 2rpm, duk wanda ya fi girma | |
Wasu | Tushen wutan lantarki | 100 ~ 240Vac, 50/60Hz |
Batirin da aka gina a ciki | 4400mAh baturi lithium | |
Nunawa | 12.1 inch (Resolution 800*600) | |
Yanayi mai ban tsoro | Ƙararrawa mai ji-na gani | |
tashar sadarwa | Ethernet tashar jiragen ruwa | |
Daidaitaccen Kanfigareshan | ECG, RESP, SpO 2, NIBP, TEMP, PR | |
Zabin | 2-IBP, EtCO, Nellcor Spo, SunTech NIBP, Fitar da zuciya, Built in printer, Cerebral State Monitoring, Central monitoring system, Touch Screen |